Function tests – Genie IWP Super Series 48643 User Manual

Page 16

Advertising
background image

14

Genie IWP Super Series

Part No. 48643

Operator’s Manual

Second Edition • Fourth Printing

Test Interlock System

9 Pump the foot pedal to raise the base.

Result: The two foot pad display lights should be

off.

10 Pull the base lowering handle to lower the base.

Result: The two foot pad display lights should be

on.

11 Pump the foot pedal to raise the base.

12 Turn both the leveling jacks clockwise to the full

down position.

13 Pull the base lowering handle to lower the

base.

Result: The base will lower and the two level

sensor display lights should be off and remain
off because the base is not level.

14 At the platform controls, push in the control

activate button and rotate the up/down switch to
the

UP

position, then the

DOWN

position.

Result: The platform up/down function should

not operate.

Test Emergency Stop

15 Use the bubble level and adjust the leveling

jacks until the machine base is level. Be sure
all four display lights are on.

16 Push in the red Emergency Stop button at the

ground controls.

17 At the platform controls, push in the control

activate button and rotate the up/down switch in
each direction.

Result: The platform up/down function should

not operate.

18 Push in the red Emergency Stop button at the

platform controls and pull out the red
Emergency Stop button at the ground controls.

19 At the platform controls, push in the control

activate button and rotate the up/down switch in
each direction.

Result: The platform up/down function should

not operate.

FUNCTION TESTS

Function Tests

1 Select a level test area free of obstructions.

2 Pump the foot pedal to

raise the base.

Result: The wheels

should contact the
ground.

3 Pull the base lowering

handle to fully lower the
base.

Result: All four foot

pads should come in
firm contact with the
ground.

4 Connect the appropriate power source.

5 Use the bubble level and adjust the leveling

jacks until the machine is level and all four foot
pads are in firm contact with the ground.

6 Insert the key and turn to the

ON

position OR

turn to platform controls.

7 Pull out the red Emergency Stop button at the

ground controls to the

ON

position.

8 Twist to release the red Emergency Stop button

at the platform controls.

Result: The power light

should come on. Within
1 to 4 seconds, all four
display lights should turn on
and remain on.

Advertising