Operating instructions, Do not operate unless, Fundamentals – Genie IWP Super Series 48643 User Manual

Page 19: Setup

Advertising
background image

Part No. 48643

Genie IWP Super Series

17

Operator’s Manual

Second Edition • Fourth Printing

Operating Instructions

Do Not Operate Unless:

You learn and practice the principles of safe

machine operation contained in this operator's
manual.

1 Avoid hazardous situations.

2 Always perform a pre-operation inspection.

3 Always perform function tests prior to use.

4 Inspect the work place.

5 Only use the machine as it was intended.

Fundamentals

Using the machine for anything other than lifting
personnel and tools to an aerial work site is
unsafe.

If more than one operator is expected to use a
machine at different times in the same work shift,
each operator is expected to follow all safety rules
and instructions in the operator's manual. That
means every new operator should perform a pre-
operation inspection, function tests and a work
place inspection before using the machine.

Setup

1 Pump the foot pedal to

raise the base until the
wheels contact the
ground.

2 Use the steering handle

to push the machine.

3 Position the machine on a firm, level surface

directly below the work area.

4 Pull the base lowering

handle to lower the base
until all four foot pads are
in firm contact with the
ground.

5 Connect to an appropriate power source:

DC models: Connect battery pack.
AC models: Connect to a grounded
15A AC power supply. Use a 12 gauge / 3.3mm

2

3-wire grounded extension cord no longer than
50 feet / 13 m.

6 Insert the key and turn to the

ON

position OR to

platform control.

7 Pull out the red Emergency Stop button at the

ground controls and be sure the power light is
on.

8 Check the interlock display. Be sure that all four

display lights are on.