Isocyanate Hazard

10

309550U

Isocyanate Hazard

Keep A and B
Components
Separate

Grounding

Check your local electrical code and proportioner man-
ual for detailed grounding instructions.

Ground the spray gun through connection to a
Graco-approved grounded fluid supply hose.

Piston Safety Lock

Engage piston safety lock whenever you stop spray-
ing, to avoid accidental triggering.

WARNING

Read Material Safety Data Sheet (MSDS) to know the
specific hazards of isocyanates. Use equipment in a
well-ventilated area. Wear respirator, gloves, and pro-
tective clothing when using isocyanates.

CAUTION

To prevent cross-contamination of the gun’s wetted
parts, do not interchange A component (isocyanate)
and B component (resin) parts. The gun is shipped
with the A side on the left. The fluid manifold, fluid
housing, side seal cartridge, check valve cartridge,
and mix chamber are marked on the A side.

WARNING

Read warnings, page 8.

WARNING

Read warnings, page 7.

To engage piston safety lock: push knob in and turn
clockwise. If engaged, gun will not actuate.

To disengage piston safety lock: push knob in and
turn counterclockwise until it pops out. There will be a
gap between knob and gun body.

TI2409A

Engaged

TI2410A

Disengaged