Setup

12

309550U

Setup

* (W) Not included with spatter gun.

1.

Close fluid valves A and B.

2.

Connect A (ISO) and B (RESIN) fluid hoses to fluid

manifold.

3.

Engage piston safety lock, page 10.

4.

Connect gun air whip hose (V) and air valve (W*)

to main air hose. Attach fluid manifold (M) to gun.

TI2411A

A (ISO)

B (RESIN)

TI2417A

TI2409A

TI2554A

V

M

W*

To change position of fluid manifold or use
optional fluid inlets, see pages 16 and 17.

5.

Connect quick coupler (D). Turn on air. Open air

valve (W*). Air should flow from nozzle (N).

To use optional air inlet, see page 17.

6.

Disengage piston safety lock, page 10.

7.

Trigger gun to check for full mix chamber travel.

Front of air cap (C) should be approximately flush
with front retaining ring (U).

TI2414-1A

D

N

W*

TI2410A

TI2414-1A

C

U