Piston safety lock air valve – Graco FUSION 309550U User Manual

Page 33

Advertising
background image

Repair

309550U

33

Piston Safety Lock

Air Valve

1.

Follow Pressure Relief Procedure, page 15.

2.

Disconnect air (D) and remove fluid manifold (M).

3.

Unscrew cylinder cap (5). Hold piston stop (28)

with wrench and unscrew from safety lock (4).
Inspect spring (30) and o-rings (14, 24).

4.

Liberally lubricate o-rings and reassemble. Clean

threads with solvent or alcohol. Apply
medium-strength Loctite

® or equivalent to threads

on stop (28) and reassemble.

5.

Attach fluid manifold. Connect air. Return gun to

service.

TI2554A

M

D

5

14

28

24

30

4

TI2433A

1.

Follow Pressure Relief Procedure, page 15.

2.

Disconnect air (D) and remove fluid manifold (M).

3.

Unscrew air valve plug (2) and remove spring (31).

Using a small diameter tool, push spool (32) out
from front. Inspect o-rings (24).

4.

Liberally lubricate o-rings and reassemble. Torque

plug (2) to 125-135 in-lb (14-15 N•m).

5.

Attach fluid manifold. Connect air. Return gun to

service.

TI2554A

M

D

24

32

31

2

TI2434A

Advertising