Before beginning installation – GE GXRV10ABL01 User Manual

Page 11

Advertising
background image

11

Consumer Support

Tr

oubleshooting T

ips

Operating Instructions

Safety Instructions

Installation Instructions

Things to Check Before Beginning Installation

FEED WATER—The water supply to the undercounter
Reverse Osmosis system must have the qualities listed
in the specifications (see the Specifications Guidelines
section). Municipal water supplies most often will have
these qualities. Well water may need conditioning—
have the water tested by a water analysis laboratory
and get their recommendations for treatment.

CAUTION: For water with a hardness greater
than 10 grains (at 6.9 pH), the use of a softener is
recommended. Failure to install a softener will reduce
the life of the Reverse Osmosis membrane. See the
Specifications Guidelines section for additional
information on the possible need for a softener.

DRAIN POINT*—A suitable drain point and air gap
(check your local codes) are needed for reject water
from the Reverse Osmosis membrane cartridge.

RO FAUCET—The RO product water faucet installs on
the sink or on the countertop next to the sink. Often,
it is installed in an existing sink spray attachment hole.
Space is required underneath for tubing to and from the
faucet, and for securing the faucet in place. All faucet
connections and installation procedures are done on or
above the sink or countertop. Refer to Fig. 1 below.

BASEMENT INSTALLATION—If installing in a basement,
leave enough tubing in place during installation to be
able to move unit to floor for ease at servicing and
making filter/membrane changes.

Fig. 1. INSTALLATION
OVERVIEW

Sump wrench

provided

RO product water faucet
mounted through sink

3/8

drain tubing

Water supply
valve or
compression
fitting

Hot Cold

Sink p-trap

Drain line*

6-1/4

15

16

9

″ dia.

17

Depth

5 1⁄2

Reverse Osmosis system

Storage tank

*For drain line options see Filtration Drain Connection Installations section.

Advertising