Step-by-step installation instructions – GE GXRV10ABL01 User Manual

Page 14

Advertising
background image

Filtration Drain Connection Installations

Secondary Recommendation
(Use only if option A, B or C on page 13
is not possible.)

OPTION D.
DRAIN LINE ADAPTER INSTALLATION (Fig. 3D)

DO NOT install the drain line downstream of a
disposal or in a horizontal pipe.

Install the provided

drain line adapter under the sink as shown.
The baffle-tee or y-connector shown must be in place
(purchase and install if necessary) to prevent a clog in
the Reverse Osmosis drain line. Route the drain line
from the air gap to the drain line adapter ensuring
that there are no dips, loops or low spots in the line,
which could result in a clogged drain line. The drain
line adapter should be aligned vertically so that the
hose connection points in a direction 45°off vertical.
(See Fig. 3E.) This installation MAY result in a slight
drain noise in the sink drain when the Reverse
Osmosis system is operating. Rotate the Drain Line
adapter tee assembly slowly until noise is minimized.
Generally, 180° opposite the existing horizontal
pipe/baffle-tee is a good orientation.

CAUTION!

DO NOT INSTALL DRAIN LINE ADAPTER
DOWNSTREAM FROM DISPOSER.

When installed, the tubing must not have any dips,
kinks, loops, etc. The tubing must be cut to length
to provide a straight routing from the faucet to the
drain (Fig. 3F). See instructions in the “Filtration
Drain Connection Installation”
section for details
and options.

INCORRECT INSTALLATION WILL RESULT IN WATER
BACK-UP IN THE DRAIN LINE, WHICH WILL LEAK AT
THE FAUCET!

Fig. 3D.

Fig. 3E.

Mandatory baffle-tee
or y-connector

From second
sink or disposer

45°

From faucet air gap

Drain line
adapter

Drain line connection should be 180°
opposite existing horizontal
pipe/baffle-tee as shown in diagram

Drain line adapter

Proper drain line adapter orientation.

Step-by-step installation instructions.

Consumer Support

Tr

oubleshooting T

ips

Operating Instructions

Safety Instructions

Installation Instructions

Installation Instructions

14

Fig. 3F.

Drain line adapter

Drain line
is straight

Drain line adapter
in different line
from disposer

Disposer

HOT

COLD

Advertising