Qmain menu → record → alarm record rate – GE Security DVMRe Triplex 0150-0193G User Manual

Page 38

Advertising
background image

0150-0193G

38

DVMRe Triplex

versa. The maximum record rate for multiple cameras is 48pps (NTSC)(40pps PAL). The maximum
record rate for a single camera is 30pps (NTSC)(25pps PAL).

The bottom right corner of the menu contains a record duration calculator. The top line indicates the
estimated recording time of the cameras in Activity record mode only. The bottom line indicates the
estimated recording time, taking into consideration the amount of time the unit will spend in Time-lapse,
Activity, Event, and/or Alarm record mode.

Activity Record Rate

Camera 1 :

Camera 2 : 0.29 pps 3.5 spp

Camera 3 : 0.34 pps 2.9 spp

Camera 4 : 0.57 pps 1.8 spp

:

:

:

Camera 15 : 0.40 pps 2.5 spp

Camera 16 : 0.40 pps 2.5 spp

0.40 pps 2.5 spp

[CANCEL] [OK]

68 days 11 h (ACTIVITY)

9 days 16 h (Total)

% Time: 4%

Estimate of the % of time each
camera will typically spend in

periods of activity. For example
if you expect to have about 20
total periods of activity each day,

each lasting 3 minutes on average,
then the % of the time will be 4%.
(1 hour/24 hours)

% Time: 4%

1. Rotate the Jog to navigate, and the Shuttle to change the values.

2. To save changes and exit the menu: Select [OK], and then press the Enter button.

3. To exit the menu without making changes: Press the Menu button, or select [CANCEL], then

press the Enter button.

q

Main Menu

→ Record → Alarm Record Rate

During an alarm, the unit records at the alarm record rate. The bottom of the menu contains a record
duration calculator. The top line indicates the estimated recording time of the cameras in Alarm record
mode only. The bottom line indicates the estimated recording time, taking into consideration the amount
of time the unit will spend in Time-lapse, Activity, Event, and/or Alarm record mode.

The configuration of the Alarm Record Rate is closely associated with the Alarm Record Mode. For
detailed information about configuring the Alarm Record Mode, see Alarm Record mode in section 3.11.

Global Alarm Record Rate

[CANCEL] [OK]

% Time:

60 pps

40 days 20 h (Alarm)

15 days 11 h (Total)

1%

Estimate of the % of time the

unit will typically spend in
alarm mode. For example

if you expect to have about 5

total periods of alarms each day,
each lasting 3 minutes on average,

then the % of the time will be 1%.

(15 min/24 hours)

Record
Duration

Calculator

1. Rotate the Jog to navigate, and the Shuttle to change the values.

2. To save changes and exit the menu: Select [OK], and then press the Enter button.

3. To exit the menu without making changes: Press the Menu button, or select [CANCEL], then

press the Enter button.

Advertising