11 alarms, Qmain menu → record → auto delete mode, Qmain menu → alarms → input configuration – GE Security DVMRe Triplex 0150-0193G User Manual

Page 41

Advertising
background image

0150-0193G

41

DVMRe Triplex

q

Main Menu

→ Record → Auto Delete Mode

The ADM feature prevents the unit from displaying or archiving any search results that are more than
thirty days old. This feature may be required by law in some jurisdictions. Choose from 1 to 99 days or
Off. The default setting is Off.

ADM will change. Are you sure?

Message

ADM Setting

99

Days

Yes

3.11 Alarms

Use this menu to configure the alarm handling features of the unit.

Caution! The DVMRe Triplex’s primary function is to furnish
video multiplexing and recording with a multiscreen display.
Although the unit has alarm handling and motion detection
functions, these are considered secondary features. This unit
should not be the only alarm device on site.

q

Main Menu

→ Alarms → Input Configuration

Configure the alarm inputs as either Normally Open or Normally Closed.

Configure inputs as follows.

Normally Open Zero Potential Relay Contact: Configure in menu as
Normally Open.

Normally Closed Zero Potential Relay Contact: Configure in menu
as Normally Closed

TTL Active High: Configure in menu as Normally Closed.

TTL Active Low: Configure in menu as Normally Open.

Open Collector Active On: Configure in menu as Normally Open.

Open Collector Active Off: Configure in menu as Normally Closed.

Alarm Latch

Alarm Action

Alarm Record Mode

Enable / Disable

Alarm History

Link to a Macro

Fullscreen Alarm

Relay Configuration

Buzzer Setup

Videoloss Action

Pre Alarm Duration

Notification

Archive Alarms

Input Configuration