Welding power source input power connections, 5. welding power source input power connections – Miller Electric Inverter Rack User Manual

Page 16

Advertising
background image

OM-818 Page 12

3-5.

Welding Power Source Input Power Connections

Y

Disconnect input power to rack
before working on wiring for any
welding power source.

Have only qualified persons make this instal-
lation.

1

Control Box

Open access door on front of control box.

2

Strain Relief Connector

3

Welding Power Source Input Power
Cord

Each welding power source location on the

rack is numbered. The numbers on the con-
trol box access door refer to the similarly lo-
cated strain relief connectors and circuit
breakers inside the control box. Insert power
cord into strain relief with number matching
location of welding power source on rack.

4

Grounding Conductor − Green Or
Green With Yellow Stripe(s)

5

Grounding Terminal

Install grounding conductor to grounding
terminal.

6

Input Conductors

7

Power Circuit Breaker Terminals

.

When installing conductors from the
welding power source, torque the Power
circuit breaker terminals and grounding
terminal to 40 in-lbs (4.5 N

·m).

Install input conductors from welding power
source to Power circuit breaker nearest entry
for input conductors.

Tighten strain relief connector. Close and se-
cure access door.

Ref. ST-801 703 / ST-801 699

Tools Needed:

1

2

3

6

4

5

7

1

Side View

Advertising