NPort 5600 Series User’s Manual

Web Console Configuration

Port alias

Setting

Factory Default

Necessity

1 to 15 characters
(E.g., PLC-No.1)

None Optional

“Port Alias” is specially designed to allow easy identification of the serial devices which are
connected to NPort’s serial port.

Serial Parameters

Check the serial communication parameters in your Serial Device’s user’s manual. You should
set up NPort’s serial parameters with the same communication parameters used by your serial
devices.

Baud rate

Setting

Factory Default

Necessity

50 bps to115.2 Kbps

115.2 Kbps

Required

Data bits

Setting

Factory Default

Necessity

5, 6, 7, 8

8

Required

When the user sets Data bits to 5 bits, the stop bits setting will automatically change to 1.5 bits.

Stop bits

Setting

Factory Default

Necessity

1, 2

1

Required

Stop bits will be set to 1.5 when Data bits is set to 5 bits.

Parity

Setting

Factory Default

Necessity

None, Even, Odd, Space, Mark

None

Required

5-10