Real com mode, Real com mode -12 – Moxa Technologies 5600 User Manual

Page 38

Advertising
background image

NPort 5600 Series User’s Manual

Web Console Configuration

Real COM Mode

TCP alive check time

Setting

Factory Default

Necessity

0 to 99 min

7 min

Optional

0 min: TCP connection is not closed due to an idle TCP connection.

1 to 99 min: NPort automatically closes TCP connection if there is no TCP activity for the given
time. After the connection is closed, NPort starts listening for another Real COM driver
connection from another host.

Max connection

Setting

Factory Default

Necessity

1, 2, 3, 4

1

Required

Max connection is usually used when the user needs to receive data from different hosts
simultaneously. The factory default is 1. In this case, only one specific host can access this port of
the NPort, and the Real COM driver on that host will have full control over the port.

Max. connection 1:
Allows only 1 host’s Real COM driver to open the specific NPort serial port.

Max connection 2 to 4:
Allows 2 to 4 hosts’ Real COM drivers to open the specific NPort serial port at the same time.
When multiple hosts’ Real COM drivers open the serial port at the same time, the COM driver
only provides a pure data tunnel without control ability. That is, this serial port parameter will use
firmware’s settings, not depend on your application program (AP).

Application software that is based on the COM driver will receive a driver response of “success”
when the software uses any of the Win32 API functions. The firmware will only send the data
back to the driver on the host.

Data will be sent first-in-first-out when data comes into the NPort from the Ethernet interface.

5-12