NPort 5600 Series User’s Manual

Web Console Configuration

NPort should send that series of characters during a time interval less than the Force Transmit
timeout for NPort, and the total length of data must be less than or equal to NPort’s internal buffer
size. The serial communication buffer size for NPort is 1 KB per port.

Destination IP address 1

Setting

Factory Default

Necessity

IP address or Domain Address
(E.g., 192.168.1.1)

None Required

Allows NPort to connect actively to the remote host whose address is set by this parameter.

Destination IP address 2/3/4

Setting

Factory Default

Necessity

IP address or Domain Address
(E.g., 192.168.1.1)

None Optional

Allows NPort to connect actively to the remote host whose address is set by this parameter.

Up to 4 connections can be established between NPort and hosts. The connection speed or
throughput may be low if one of the four connections is slow, since the 1 slow connection will
slow down the other 3 connections.

The “Destination IP address” parameter can use both IP address and Domain Name. For some
applications, the user may need to send the data actively to the remote destination domain name.

TCP connect on

Setting

Factory Default

Necessity

Startup,
Any Character

None Optional

Startup: Attempts to establish a TCP connection as soon as the NPort is powered on.

Any Character: Attempts to establish a TCP connection as soon as the NPort starts receiving serial
data.

5-19