Ip setup > http configuration – Multi-Tech Systems MULTIMODEM MTCBA-C-EN-NX User Manual

Page 23

Advertising
background image

Chapter 3 – Using the Web Management Software

Multi-Tech Systems, Inc. MultiModem Wireless Modem with Ethernet Interface (S000375F)

23

General Configuration

Date and Time:

The system date and time display in these formats: DD/MM/YYYY / HH:MM:SS. SNTP Client

must be enabled and you must have a live Internet connection for the date and time to display correctly.

IP Configuration

Enter the following addresses for the Ethernet interface.
IP Address (Default = 192.168.2.1), Mask (Default 255.255.255.0), Default Gateway (Default 0.0.0.0),

Primary DNS (Default 0.0.0.0), Secondary DNS (Default 0.0.0.0).

Note:

See Appendix A – Table of Commonly Supported Subnets.

Auto Dialout Configuration

Auto Dialout:

Check the box to enable/disable Auto Dialout. Default = Enable.

Raw Dialout:

Check the box to enable/disable raw mode for an Auto Dialout session. Default = Disable.

Auto Dialout Login:

Check the box to enable or disable Auto Dialout Login feature. Default = Enable.

Auto Dialout Port:

Enter the serial Auto Dialout Port number. Default = 5000.

Handle EIA Signal:

Check the box to enable/disable the EIA standard signal characteristics (time and

duration) used between different electronic devices.

Inactivity:

Enter the time in seconds that the auto dialout session will stay active before going inactive.

Syslog Configuration

Syslog:

Check the box to enable or disable Syslog. Default = Disable.

Syslog Server IP Address:

If a Remote Syslog Server IP Address is specified, the syslog feature acts as a

remote Syslog.

Auto Discovery

Auto Discovery:

Check the box to enable or disable Auto Discovery to broadcast (MAC level), the MAC

Address, IP Address, and DHCP information to the configured server port. Default = Enable.

Server Port:

Enter the Server Port Number. Default port is 1020.

Broadcast Timer:

Enter the amount of time in seconds for the auto-discovery packet granularity of periodic

broadcasting. Default is 10 seconds.

Auto Reboot Timer Configuration

Auto Reboot Timer:

Enter the number of hours to lapse between each automatic reboot. The default of zero

deactivates the timer. Range is 0 to 999.

Telnet Configuration

Enables/Disables the Telnet port. The default is Enable.

Submit Button

Click the Submit button to save these settings.

Note:

You must click Save and Restart once you have

completed and submitted all the screens on which you have made changes.

IP Setup > HTTP Configuration

HTTP Configuration

HTTP Port:

Enter the port number on which the HTTP server will listen for requests. Default is 80.

Authentication

User Name:

Enter the User Name that can access to the Web Management software. Default is admin.

Password:

Enter the Password for access to the Web Management software. Default is admin.

Note:

You should change the password to one of your choosing. It can be up to 12 characters. Use a safe

password. Your first name spelled backwards is not a sufficiently safe password; a password such as xfT35$4

is better.

Submit Button

Click the Submit button to save these settings.

Note:

You must click Save and Restart once you have

completed and submitted all the screens on which you have made changes.

Advertising
This manual is related to the following products: