Specifications

Input

Power

Rated Welding

Output

Amperage

Range

Voltage

Range

Maximum

Open-

Circuit

Amperes Input

At Rated Load

Output 60 Hz,

Three-Phase

Voltage DC

400 V

KVA

KW

Three

Phase

450 A @ 38 Volts DC,

100% Duty Cycle;

565 A @ 38 Volts DC,

60% Duty Cycle

5 – 600

10 – 38

95

31

21.6

19.4

3-2.

Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.

If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.

Y

Exceeding duty cycle can
damage unit and void war-
ranty.

Overheating

0

15

A/V

OR

Reduce Duty Cycle

Minutes

duty1 4/95 – SA-181 560

Continuous Welding

100% Duty Cycle At 450 Amperes

60% Duty Cycle At 565 Amperes

6 Minutes Welding

4 Minutes Resting