7. remote 14 receptacle information – Miller Electric 456 CV User Manual

Page 21

Advertising
background image

OM-188 422 Page 17

3-7.

Remote 14 Receptacle Information

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit breaker CB2.

24 VOLTS AC

B

Contact closure to A completes 24 volts ac con-
tactor control circuit.

A

J

B

K

I

115 VOLTS AC

I

115 volts ac. Protected by circuit breaker CB1.

B

C

L

N

H

D

M

G

115 VOLTS AC

J

Contact closure to I completes 115 volts ac con-
tactor control circuit.

E

F

C

Output to remote control; +10 volts dc in MIG
mode.

D

Remote control circuit common.

REMOTE

OUTPUT

CONTROL

E

0 to +10 volts dc input command signal from re-
mote control.

M

Mode select.

N

Remote inductance control.

A/V

AMPERAGE

F

Current feedback; +1 volt dc per 100 amperes.

Ref. ST-802 260

AMPERAGE

VOLTAGE

H

Voltage feedback; +1 volt dc per 10 arc volts.

G

Circuit common for 24 and 115 volts ac circuits.

GND

K

Chassis common.

*The remaining sockets are not used.