10. connecting input power – Miller Electric 456 CV User Manual

Page 23

Advertising
background image

OM-188 422 Page 19

3-10. Connecting Input Power

ssb2.4* 1/94 – ST-801 523-B / ST-801 946

Tools Needed:

5/16 in

Input Filter

Board

L1

=GND/PE

Y

Always connect
grounding conductor
first.

Y

Turn Off welding power source, and
check voltage on input capacitors ac-
cording to Section 5-3 before
proceeding.

Check input voltage available at site.

Remove left side panel.

1

Input And Grounding Conductors

See Section 3-9.
Install ring terminals of proper size onto input
conductors for connection to input filter
board terminals (see illustration).
2

Line Disconnect Device

Select type and size of overcurrent protec-
tion using Section 3-9. Connect input and
grounding conductors to a deenergized line
disconnect device.

Reinstall left side panel.

L1

2

L2

L3

1

L2

L3