1. installing welding generator – Miller Electric Big Blue 401DXQ User Manual

Page 21

Advertising
background image

OM-173 413 Page 17

SECTION 4 – INSTALLATION

4-1.

Installing Welding Generator

install1 3/96 – Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854

1

2

Electrically bond generator frame to
vehicle frame by metal-to-metal
contact.

GND/PE

3

4

1

Generator Base

2

Metal Vehicle Frame

3

Equipment Grounding
Terminal

4

Grounding Cable

Use #10 AWG or larger insulated
copper wire.

Y

If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.

2

OR

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

OR

Movement

Airflow Clearance

Location

Grounding

OR

Y

Do Not Lift Unit From End

Advertising