OM-173 413 Page 25

6-3.

Connecting Optional Auxiliary Power Plant

Ref. S-188 059-A

Y

Stop engine.

Y

Power and weld outputs are
live at the same time.
Disconnect or insulate
unused cables.

.

Have qualified person install
according to circuit diagram
and Auxiliary Power Guidelines
(Section 10).

Remove junction box cover.

1

Lead 93

2

Lead 92

3

Lead 91

4

Lead 90 (Neutral)

5

Lead 42 (Circuit Grounding
Lead)

Lead 42 connects to front panel
Ground stud.

6

Grounding Terminal

7

Jumper Lead 42

8

Isolated Neutral Terminal

Jumper 42 is connected to lead 90
at factory. Jumper 42 may be dis-
connected from neutral to meet
applicable electrical codes.

9

User Supplied Leads

10 Load Terminals

Connect leads to terminals.

11 Fuses F1, F2, And F3

F1, F2, and F3 protect each load line
from overload.

.

Set Engine Control switch to
Run when using auxiliary
power.

92

90

91

93

Tools Needed:

F3

F2

F1

3

5

4

6

7

8

10

11

Volts

Amps

KVA/KW

Single

120/240

31

7.5

Three

240

24

10

60 Hz

Frequency

Engine Speed

Max. Fuse Size

35 Amperes

1850 RPM

AC

Phase

1

Phase

3

Output

Lead 42 connects to GROUND stud on front of
unit.
Jumper 42 is connected to 90 at factory.

1

2

9