1. routine maintenance, 3 months, 6 months – Miller Electric 255 User Manual
Page 20: 2. circuit breaker cb1
Advertising
OM-157 066 Page 16
SECTION 4 – MAINTENANCE & TROUBLESHOOTING
4-1.
Routine Maintenance
Y
Disconnect power
before maintaining.
.
Maintain more often
during severe conditions.
3 Months
Replace
Damaged Or
Unreadable
Labels
Clean And
Tighten
Weld
Terminals
Repair Or
Replace
Cracked
Cables And
Cords
6 Months
Blow Out Or
Vacuum Inside
Remove drive roll and
carrier. Apply light coat
of oil or grease to drive
motor shaft.
4-2.
Circuit Breaker CB1
Ref. ST-800 924-C
1
Circuit Breaker CB1
If CB1 opens, wire feeding stops.
2
Welding Gun
Check gun liner for blockage or
kinks.
3
Wire Drive Assembly
Check for jammed wire, binding
drive gear or misaligned drive rolls.
Allow cooling period and reset
breaker. Close door.
1
2
3
Advertising