3. fuses f1 and f2, 4. changing drive roll and wire inlet guide, 5. replacing gun contact tip – Miller Electric 255 User Manual
Page 21
OM-157 066 Page 17
4-3.
Fuses F1 And F2
Ref. ST-800 928-B
Y
Turn Off unit, and disconnect
input power.
1
Fuse F1 (See Parts List For
Rating)
F1 protects the 115 volts ac winding
of transformer T1. If F1 opens, all
weld output stops and pilot light PL1
goes out.
2
Fuse F2 (See Parts List For
Rating)
F2 protects the 24 volts ac winding
of transformer T1. If F2 opens, all
weld output stops.
2
1
3/8 in
Tools Needed:
4-4.
Changing Drive Roll And Wire Inlet Guide
ST-150 227-D
1
Securing Screw
2
Inlet Wire Guide
Loosen screw. Slide tip as close to
drive rolls as possible without
touching. Tighten screw.
3
Anti-Wear Guide
Install guide as shown.
4
Drive Roll
Install correct drive roll for wire size
and type.
5
Drive Roll Securing Nut
Turn nut one click to secure drive
roll.
5/64 in
7/16 in
Tools Needed:
1
3
2
4
5
4-5.
Replacing Gun Contact Tip
Ref. 800 797-C
Y
Turn Off unit before
replacing contact tip.
1
Nozzle
2
Contact Tip
Cut off welding wire at contact tip.
Remove nozzle.
Remove contact tip and install new
contact tip. Reinstall nozzle.
1
2
Tools Needed: