Section 4 − operation, 1. controls – Miller Electric 3080 User Manual

Page 18

Advertising
background image

OM-2225 Page 14

SECTION 4 − OPERATION

1

Gas/Air Pressure Gauge

2

Gas/Air Pressure Adjustment Knob

3

Output Control

Use control to set cutting output.
Gas/air automatically flows at the set

pressure.
Use Gas/Air Set area of control range for set-

ting gas/air pressure (see Section 4-2).
4

Trouble Lights (see Section 5-2)

Power light comes On when Power switch is

placed in On position.
5

Power Light

6

Ready Light

Ready light comes On when unit is On to indi-

cate that all safety shutdown systems are

okay. If Ready light does not come On, check

trouble lights.
7

Trigger Hold Switch

To cut without holding torch trigger, depress

upper end of Trigger Hold switch, press trig-

ger to pilot, transfer torch to work, and release

torch trigger within five seconds. To stop cut-

ting, press and release trigger.
When lower end of Trigger Hold switch is de-

pressed, trigger must be held closed while

cutting.
8

Torch Quick-Disconnect Connector

9

Power Switch

10 Door for Consumables Storage

4-1. Controls

Ref. 187 861 / Ref. 802 201-B

10

9

Rear of

Unit

8

1

2

7

4

5

6

3

20

40

60

80

160

140

120

100