1

Output Control

2

Power Switch

Place controls as indicated. Only gas/air cir-

cuit is activated when the Power switch is

turned On with Output Control in Gas/Air Set

position.
3

Gas/Air Pressure Adjustment Knob

Pull knob and turn to adjust pressure. Push

knob in to lock setting.
Select desired cutting output with Output

Control.

4-2. Setting Gas/Air Pressure

Ref. 802 140 / Ref. 802 201-B

1

Set Controls

Turn On Gas/Air Supply

Adjust Pressure

On Unit

Select Desired

Amperage To Be-

gin Cutting

Set To 80 PSI

Requires

90−150 PSI Supply

Setting Gas/Air Pressure

Place Output Control in

Gas/Air Set Position

Power Switch On

Rear of

Unit

2

3