5-2. Trouble Lights

1

Pressure Light

Lights if gas/air pressure is below

60 PSI (414 kPa).
Turn power Off, and check for prop-

er gas/air pressure (see Section

4-2).
2

Cup Light

Lights if shield cup is loose.
Turn power Off, and check shield

cup connection (see torch Owner’s

Manual). Power must be reset

whenever the cup shutdown is

activated.
Check shield cup shutdown system

once a week (see Section 5-3).
3

Temperature Light

Lights if power source overheats

(see Section 3-2).

1

2

3

Difficulty establishing pilot arc may indicate

consumables need to be cleaned or replaced.

5-3. Checking Shield Cup Shutdown System

Ref. 801 300-A

1

Torch Shield Cup

Turn Power On and loosen shield

cup. If shutdown system works

properly, Ready light goes off and

Cup light comes on. If not, immedi-

ately turn Off power and have Fac-

tory Authorized Service Agent

check safety control board PC1 op-

eration.
If system works properly, retighten

cup and reset power.

1

.

Power must be reset whenever the cup shutdown
system is activated. Always turn Off power when

changing or checking consumables.