Multi-Tech Systems BA-Series User Manual

Page 59

Advertising
background image

59

Chapter 6 - Callback Security and Remote Configuration

Table 6-1. Modem LOGIN, Setup and Remote Escape Code Procedures

To change your modem’s LOGIN Password and Setup Password:

Step

Procedure

Note: Passwords are upper/lower case sensitive. The case you enter here is the case that must be
used at Log-In.

1.

Type

AT#IMULTI-TECH and hit RETURN. Your modem will respond with:

OK (if the LOGIN Password is wrong, the modem’s response is ERROR)

2.

Type

AT#SMODEMSETUP and hit RETURN. Your modem will respond with the following:

OK (or ERROR if wrong Setup Password)

Note: At this point you can change the LOGIN Password and Setup Password.

3.

Type

AT#I=xxxxxxxxxx (with any keyboard characters used, minimum 6 maximum 10) and hit

RETURN. Your modem responds with:

OK

4.

Type

AT#S=yyyyyyyyyy (with keyboard characters used, minimum 6 maximum 10) and hit

RETURN. Your modem responds with:

OK

To change your Remote Configuration feature status:

5.

If you want Remote Configuration off, set S-Register S13 to 0 (zero). Refer to Chapter 6 for
details on how to set S-Register values.

6.

If you want Remote Configuration on and wish to change the Remote Escape Character, change
the S-Register S13 value. If you leave it at the default value, decimal 37 (% sign) will be your
modem’s remote escape character.

To turn your modem's Callback Security feature on and off:

7.

If you want Callback Security with both remote and local password security, enter

AT#DB1 and

hit RETURN. You must turn on Callback Security to be able to enter dial back phone numbers.

8.

If you want Callback Security on with just remote password security, enter

AT#DB2 and hit

RETURN. You must turn on Callback Security to be able to enter dial back phone numbers. If
you want to use your modem to call another modem that is also set for Callback, you must enter
AT#DB3 before you dial.

Note: this is for your modem if you are set for #DB1 or #DB2.

Once you have disconnected from that call, your modem will go back to its original setting.

9.

If you want Callback Security turned off, type

AT#DB0 and hit RETURN.

To set parity of the password/message prompt:

10. The parity default value for your modem is no parity (

AT#P0). If your modem's prompt messages

use even parity, enter

AT#P2 and hit RETURN. For odd parity, enter AT#P1 and hit RETURN.

11. Enter the

&W0 command and hit RETURN to store parameters and S-Register values in RAM.