Chapter 7 - DIP-Switch Settings

Switch #2
SDLC/BSC Option
(Synchronous Mode/Leased Line/Dial-Up)

Synchronous Data Link Control (

SDLC) and Binary Synchronous Control (BSC) are two error

correction protocols used in the IBM Mainframe environment. Place DIP-Switch #2 in the UP position
to enable SDLC mode, and place DIP-Switch #2 in the DOWN position to enable BSC mode.

SDLC Mode

=

Switch #2 UP

BSC Mode

=

Switch #2 DOWN

Factory Default Setting =

UP

Switch #3
Enable/Suppress Responses -- "Q"
(Asynchronous Mode/Dial-Up)

In some Asynchronous mode applications, you may want to suppress all responses from the modem.
Place DIP-Switch #3 in the DOWN position to enable Result Code responses (

Q0). Place DIP-Switch

#3 in the UP position, and answer mode is handled without responses and echo turned off (

Q2), but

originate is still intelligent.

Enable Responses: Originate/Answer (

Q0)

=

Switch #3 DOWN

Suppress Responses: Answer (

Q2)

=

Switch #3 UP

Factory Default Setting

=

DOWN

Switch #3
dB Transmission Levels
(Asynchronous/Synchronous Mode/Leased Line)

DIP-Switch #3 adjusts dB transmission levels required by some phone carriers. Place DIP-Switch #3
in the DOWN position to enable -9 dB transmission. Place DIP-Switch #3 in the UP position to enable
-15 dB transmission.

-9dB Transmission

=

Switch #3 DOWN

-15dB Transmission

=

Switch #3 UP

Factory Default Setting =

DOWN

Switch #4
AS/400 Mode
(Synchronous Mode/Leased Line/Dial-UP)

The modem can function in the IBM AS/400 environment (appearing like an IBM5853 modem). First,
DIP-Switch #7 must be placed in the UP position. This establishes an RTS/CTS condition (state
typical for an IBM5853 modem in half-duplex mode). Next, place DIP-Switch #4 in the DOWN
position. This

"spoofs" the modem into operating like an IBM5853 modem in AS/400 applications.

DIP-Switch #4 in the UP position disables this function. Note that the modem must be in Command
mode to allow AS/400 mode (DIP-Switch #8 DOWN); and in Synchronous mode (DIP-Switch #12
UP).

AS/400 Mode Enabled =

Switch #4 DOWN

AS/400 Mode Disabled =

Switch #4 UP

Factory Default Setting =

UP