2 remote configuration procedures, Remote configuration procedures – Multi-Tech Systems BA-Series User Manual

Page 61

Advertising
background image

61

Chapter 6 - Callback Security and Remote Configuration

7.

Enter your modem's LOGIN Password (as selected in Table 6-1) by entering:

AT#Ixxxxxxxxxx<CR> (xxxxxxxxxx from Table 6-1)

8.

Enter your modem's Setup Password (as selected in Table 6-1) by entering:

AT#Syyyyyyyyyy<CR> (yyyyyyyyyy from Table 6-1)

Table 6-3. Callback Operational Sequence Procedures

Perform the following steps when dialing into a dialback modem:

Step

Procedure

1.

When called, the modem answers and after a slight delay, responds with:

Password>

2.

Enter your modem's LOGIN Password (Table 6-1) and hit RETURN. If entered correctly, the
modem responds with:

DB>

3.

Enter the Callback Password corresponding to the phone number you wish called back and hit
RETURN (Callback Passwords and phone numbers entered in Table 6-2). You can also use
special characters + and -. They must have been entered as part of the Callback phone numbers
in Step 5 of Table 6-2. If you use the - character along with your password, the Callback modem
will connect directly without hanging-up and calling back. If you use the + character along with
your password, you can also enter a phone number which you wish the Callback modem to dial
after hanging-up. The + and - characters must be entered after the Dial-back password, (i.e.,
DB>xxxxxx+). This is also the point where you enter an extension number if your Callback
number used the ??? feature (Step 5 in Table 6-2).

You have three tries at each prompt to enter the information properly, with an incorrect entry
resulting in a password retry. You must enter the requested information correctly within one
minute or the Callback modem will hang-up. When the information is entered properly, the called
modem will hang-up and after a 15 second delay, call you back. When your modem answers, the
dialback modem will respond with the following:

Password>

4.

Enter the modem's LOGIN Password again (the same as in Step 1). The Callback modem
responds with:

CONNECT

You are now in Data Mode.

6.3.2

Remote Configuration Procedures

The procedures for using the Remote Configuration features are the same whether or not a call
originates from the remote modem. Once the modem is on-line, perform the procedures in Table 6-4.

Table 6-4 Remote Configuration Operation Procedures

Step

Procedure

1.

Remote Escape Configuration requires %%%AT<CR> to be sent if the default value in S-
Register S13 has not been changed.

The modem responds with:

1. - DATA Mode
2. - COMMAND Mode

Advertising