Remote configuration/callback security s-registers – Multi-Tech Systems BA-Series User Manual

Page 63

Advertising
background image

63

Chapter 6 - Callback Security and Remote Configuration

Change SETUP Password

#S

The default SETUP password for your modem is

"SMODEMSETUP". If you choose to activate

callback security, you should change the SETUP password using this command in the following
format:

AT#Stttttttttt<CR> (where

tttttttttt is the current SETUP password). Your modem will respond with

"OK", indicating that you can enter the new SETUP password as follows:

AT#s=uuuuuuuuuu<CR>

You can select any combination of keyboard characters (upper/lower case sensitive) between six
and ten characters long.

Erase Callback Password

#RCBNxx

This command erases the single callback password specified by

xx (0 through 29).

Erase Callback Phone Number #RDNxx

This command erases the single phone number specified by

xx (0 through 29).

6.5

Remote Configuration/Callback Security S-Registers

The following S-Registers are used with Remote Configuration and Callback Security features.

Remote Configuration Character (S13)

S13 defines the modem’s remote configuration escape character. When the S13 character is entered
three consecutive times from a remotely connected site, your modem responds to it with its Remote
Configuration procedure.

Units:

ASCII

Range:

0-127

Default:

37 (

% sign)

Callback Time Delay (S15)

S15 defines the time delay for Callback attempts after initial passwords have been exchanged
between modems.

Unit:

Seconds

Range:

10-255

Default:

20

Callback Attempts (S16)

S16 defines the number of Callback attempts after initial passwords have been exchanged between
modems.

Unit:

1 Attempt

Range:

1-255

Default:

4

Failed Password Attempts (S26)

S26 counts the number of times there has been a failed password attempt. For example, if you
entered

ATS26? the message 003 would be displayed, meaning someone has failed three times to

gain access to your modem using its password security system.

Units:

1 failed attempt

Range:

0-255

Default:

0