External alarm, Ground data output + power + data input – Magellan NAV6000 User Manual

Page 79

Advertising
background image

Magellan NAV 6000

69

DC

Power

Black*

Red*

(+)

(-)

DC Power/RS-232
Data Cable

NMEA

Device

Black*

Orange or White

(+)

(-)

External

Alarm

Blue or Brown

Red*

(+)

(-)

DBR

Black*

Yellow or Green

(+)

(-)

* Additional red and black wire
must be spliced to connect more
than one device.

Connect DC power per

manufacturer's directions

NAV 6000 must be externally

powered to support an external alarm

Connect DC power per

manufacturer's directions

Connecting the DC Power/NMEA Data Cable (Op-
tional)

Electrical Connections

Use the power/data cable to connect the unit to an external
power source and to data devices.

The NAV 6000 accepts 9-32 VDC. It is recommend, but not
required, for a fuse (2A slow blow) to be connected to the
positive lead of the power source. See the wiring diagram to
make the necessary connections. The power/data connector
on the back of the unit has the following pin-out:

External Alarm -

5

1

2

4

3

Ground

Data Output +

Power +

Data Input -