Warning, Plan vent system – Maytag Epic W10139629A User Manual

Page 17

Advertising
background image

17

Exhaust

Recommended hood styles are shown here.

The angled hood style (shown here) is acceptable.

An exhaust hood should cap the vent to keep rodents and insects from entering the home.

Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in
the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).

Do not use an exhaust hood with a magnetic latch.

Plan Vent System

Choose your exhaust installation type

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

Optional exhaust installations

This dryer can be converted to exhaust out the right side, left side or through the bottom. If
you prefer, you may contact your local dealer to have the dryer converted.

A. Louvered hood style

B. Box hood style

4"
(10.2 cm)

4"
(10.2 cm)

B

A

4"

(10.2 cm)

2½"

(6.4 cm)

Improper venting can cause moisture and lint to collect
indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.

Housecleaning problems and health problems.

A. Dryer

B. Elbow

C. Wall

D. Exhaust hood

E. Clamps
F. Rigid metal or flexible metal vent

G. Vent length necessary to connect elbows
H. Exhaust outlet

H

G

F

E

D

C

A

B

WARNING

Fire Hazard

Cover unused exhaust holes with one of the
following kits:

279818 (white)

279820 (black)

280102 (pacific blue)

Contact your local dealer.

Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.

Advertising