TROUBLESHOOTING

First try the solutions suggested here and possibly avoid the cost of a service call...

Dryer Operation

Dryer will not run

Has a household fuse blown, or has a circuit breaker tripped?
There may be 2 household fuses or circuit breakers for the dryer. Check that both fuses are
intact and tight, or that both circuit breakers have not tripped. Replace the fuse or reset
the circuit breaker. If the problem continues, call an electrician.

Is the correct power supply available?
Electric dryers require 240-volt power supply. Check with a qualified electrician.

Was a regular fuse used?
Use a time-delay fuse.

Is the dryer door firmly closed?

Was the Start button firmly pressed?
Large loads may require pressing and holding the Start button for 2-5 seconds.

No heat

Has a household fuse blown, or has a circuit breaker tripped?
The drum may be turning, but you may not have heat. Electric dryers use 2 household
fuses or circuit breakers. Replace the fuse or reset the circuit breaker. If the problem
continues, call an electrician.

Unusual sounds

Has the dryer had a period of non-use?
If the dryer hasn’t been used for a while, there may be a thumping sound during the first
few minutes of operation.

Is a coin, button, or paper clip caught between the drum and front or rear of the dryer?
Check the front and rear edges of the drum for small objects. Clean out pockets before
laundering.

Are the four legs installed, and is the dryer level front to back and side to side?
The dryer may vibrate if not properly installed. See the Installation Instructions.

Is the clothing knotted or balled up?
When balled up, the load will bounce, causing the dryer to vibrate. Separate the load
items and restart the dryer.

Dryer displaying code message

“PF” (power failure), check the following:
Was the drying cycle interrupted by a power failure?
Press and hold START to restart the dryer.

“E” Variable (E1, E2, E3) service codes:
Call for service.

Dryer Results

Clothes are not drying satisfactorily, drying times are too long, or load is too hot

Is the lint screen clogged with lint?
Lint screen should be cleaned before each load.

Is the exhaust vent or outside exhaust hood clogged with lint, restricting air movement?
Run the dryer for 5-10 minutes. Hold your hand under the outside exhaust hood to check
air movement. If you do not feel air movement, clean exhaust system of lint or replace
exhaust vent with heavy metal or flexible metal vent. See the Installation Instructions.

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death
or fire.