Warning, Install vent system, Install leveling legs – Maytag Epic W10139629A User Manual

Page 19: Connect vent, Level dryer

Advertising
background image

19

Vent system chart

NOTE: Side and bottom exhaust installations have a 90º turn inside the dryer. To determine
maximum exhaust length, add one 90º turn to the chart.

Install Vent System

1. Install exhaust hood. Use caulking compound to seal exterior wall opening around

exhaust hood.

2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust

hood with 4" (10.2 cm) clamp.

3. Run vent to dryer location. Use the straightest path possible. See “Determine vent path” in

“Plan Vent System.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior of the vent to secure vent.

Install Leveling Legs

1. To protect the floor, use a large flat piece of cardboard from the dryer carton. Place

cardboard under the entire back edge of the dryer.

2. Firmly grasp the body of the dryer (not the console panel). Gently lay the dryer on the

cardboard. See illustration.

3. Examine the leveling legs. Find the diamond marking.

4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the

diamond marking is no longer visible.

5. Place a carton corner post from dryer packaging under each of the 2 dryer back corners.

Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent.

Connect Vent

1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to

existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust
outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a
4" (10.2 cm) clamp.

2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible gas line.
4. Once the exhaust vent connection is made, remove the corner posts and cardboard.

Level Dryer

Check the levelness of the dryer. Check levelness first side to side, then front to back.

If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs
up or down and check again for levelness.

Number of 90º
turns or elbows

Type of vent

Box or louvered
hoods

Angled hoods

0

Rigid metal
Flexible metal

64 ft (20 m)
36 ft (11 m)

58 ft (17.7 m)
28 ft (8.5 m)

1

Rigid metal
Flexible metal

54 ft (16.5 m)
31 ft (9.4 m)

48 ft (14.6 m)
23 ft (7 m)

2

Rigid metal
Flexible metal

44 ft (13.4 m)
27 ft (8.2 m)

38 ft (11.6 m)
19 ft (5.8 m)

3

Rigid metal
Flexible metal

35 ft (10.7 m)
25 ft (7.6 m)

29 ft (8.8 m)
17 ft (5.2 m)

4

Rigid metal
Flexible metal

27 ft (8.2 m)
23 ft (7 m)

21 ft (6.4 m)
15 ft (4.6 m)

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.

Advertising