Troubleshooting (cont’d)

*NOTE: To check where threaded portion enters

tank, insert cotton swab between jacket opening

and fitting. If cotton is wet, follow “Draining”

instructions in the “Service and Maintenance” sec-

tion and then remove fitting. Put pipe dope or

teflon tape on the threads and replace. Then follow

“Filling the Water Heater” instructions in the

“Instructions for Installation” section.

Leakage Checkpoints

Use this guide to check a “Leaking” water heater. Many sus-
pected “Leakers” are not leaking tanks. Often the source of
the water can be found and corrected.

If you are not thoroughly familiar with electric codes, the
water heater, and safety practices, contact your local utility or
call a Maytag Service Specialist at 1-800-365-0024 for an
authorized servicer to check the water heater.

CAUTION

Read this manual first, then before checking the
water heater make sure the electric supply has been
turned “OFF”, and never turn the electric supply
“ON” before the tank is completely full of water.

23

WARNING

HAZARD OF ELECTRICAL SHOCK! Before
removing any access panels or servicing the
water heater, make sure the electrical supply
to the water heater is turned “OFF”. Failure to
do this could result in DEATH, SERIOUS BODI-
LY INJURY, OR PROPERTY DAMAGE.

C

G

F

E

A

D

B

A

H

E

*Condensation may be seen on pipes in humid weather

or pipe connections may be leaking.

*The primary anode rod may be leaking.

Small amounts of water from temperature-pressure

relief valve may be due to thermal expansion or high

water pressure in your area.

*The temperature-pressure relief valve may be leaking

at the tank fitting.

The elements may be leaking at the tank fitting.

Turn electrical power “OFF”, remove access panels,

insulation blocks and pads. If leaking around ele-

ments, follow proper draining instructions and

remove element. Reposition or replace gasket on ele-

ment. Place element into opening and tighten

securely. Then follow “Filling the Water Heater”

instructions in the “Installation Instructions” section.

Water from drain valve may be due to the valve being

opened slightly.

*The drain valve may be leaking at the tank fitting.

*Water in the water heater bottom or on the floor may

be from condensation, loose connections or the

temperature-pressure relief valve. DO NOT replace

the water heater until a full inspection of all possible

water sources is made and necessary corrective steps

taken.
Leakage from other appliances, water lines, or ground

seepage should also be checked.