Product Specifications

Model

HRX30DERT HRX40DERS HRX40DERT HRX52DERS

Tank Capacity

In Gallons

30

40

40

50

*Element

Upper

5500

5500

5500

5500

Wattage

at 240 Volt

Lower

5500

5500

5500

5500

Recovery Rate

Upper

25

25

25

25

In Gals Per Hr.

@ 90°F Rise

Lower

25

25

25

25

Diameter

19

21

1

2

19

23

Height

47

46

60

49

Maximum Fuse or

Circuit Breaker Size

30

30

30

30

**Minimum

Wire Size (Gauge)

10

10

10

10

Model

HRX52DERT HRX66DERT HRX82DERT

Tank Capacity

In Gallons

50

66

80

*Element

Upper

5500

5500

5500

Wattage

at 240 Volt

Lower

5500

5500

5500

Recovery Rate

Upper

25

25

25

In Gals Per Hr.

@ 90°F Rise

Lower

25

25

25

Diameter

21

1

2

23

25

Height

61

61

61

1

2

Maximum Fuse or

Circuit Breaker Size

30

30

30

**Minimum

Wire Size (Gauge)

10

10

10

Advertising