5-7. Setting Internal DIP Switches

1

DIP Switch S1

2

DIP Switch S4 (Not For Customer Use)

DIP switch S1 allows the user to make a num-

ber of choices affecting unit operation.
w Defining Motor Speed (S1-7 & 8)
Switches 7 and 8 allow the user to define

whether the motor in use is standard speed

(50-780 inches per minute), or high speed

(92-1435 inches per minute), or low speed

(19-300 inches per minute).

802 808

1

2

1 2 3 4 5 6 7 8

O

N

7 8

7 8

7 8

Position Settings And Results For DIP Switch S1

7 Off, 8 Off = Standard

speed motor (50-780 inch-

es per minute, or 1.2-19.8

meters per minute)

7 On, 8 On = Low Speed

Motor (19-300 inches per

minute, or 0.4-7.6 meters per

minute).

7 Off, 8 On = High speed

motor (92-1435 inches per

minute, or 2.3-36.4 meters

per minute)

.

In the DIP switch S1 illustrations,
the elevated slider on each switch

is shown in white. For example,

the switches above are all in the

Off position.

.

When DIP switch positions are changed, the
unit must be turned Off and then On again in

order for the new settings to be active. DIP

switches are only read on power up.