5. upper display – Miller Electric S-74DX User Manual

Page 23

Advertising
background image

OM-1500-9 Page 19

6-5. Upper Display

5

2

Volts

Time (sec)

1

4

3

1

Upper Display

The upper display shows voltage or time.

The unit displays both preset and actual arc

voltage. When the unit is in a welding state,

actual arc voltage is displayed. The upper

display shows welding sequence time when

the Time LED is illuminated.
2

Upper Display Push Button

Press and hold button to adjust or display

weld time. Release button to display voltage.
3

Upper Display Push Button LED

The upper display push button LED illumi-

nates to indicate that information displayed

can be changed by the Adjust control.
4

Volts LED

5

Time LED

The LEDs below the display illuminate to in-

dicate which value is being shown.
At any time while welding, the unit permits

the adjustment of the weld sequence voltage

and overrides the display of actual arc volt-

age.

If the unit is displaying a welding sequence

that can be timed, the welding time display

mode is entered by pressing the upper dis-

play push button repeatedly until welding

time is the active parameter in the upper

display. At idle, the upper display toggles

between showing weld voltage or weld

time, with subsequent presses of the up-

per display push button.

The unit defaults to displaying welding

voltage when a welding sequence display

mode is first entered.

If the weld sequence has a time set (as in

spot time), after the weld program is com-

pleted, ERR TRG 1 will be displayed to in-

dicate the weld program is complete. Re-

lease trigger to clear error.

.

To set the correct voltage range for a particular power
source, see Section 5-8
for power source selection menu,

or Section 6-10 for V-Min And V-Max adjustments.

1

4

2

3

5

Non-CE Models

CE Models

Advertising