43

S

CALE

O

PERATION

C

ALIBRATION


Scale Calibration Procedure (lbs. or kg) with Remote Display*

4. Reinstall the platter onto the scanner/Diva scale.

Figure 44. Install Platter

5. Go

to

Group 1 Step 8 (Weight Unit) of the Service Mode by pressing the Zero ( ) key several times until

‘Group 1 Step 8’ is displayed on the Remote Scale Display screen (see Figure 45 below).

x Depending on the current Weight Unit setting, this value will either be 1, 2, 3, or 4.

Figure 45. Remote Scale Display Group 1 Step 8 example shown

6. Verify the weight unit setting. Verify the Group 1 Step 8 setting using the table shown below. Press the Zero ( ) key

if correct. If the lb (Pounds) or kg (Kilograms) basic range setting needs to be changed, press the Tare ( ) key to scroll
through the selectable options. Press the Zero ( ) key to accept the selected weight unit range.

Group 1 Step 8 (

x)

Selectable Weight Unit Ranges

1

lbs range (0 to 30 lbs) **

2

kg range (0 to 15kg)

3

kg multi-interval (0 to 6kg, 6 to 15kg) **

4

lbs multi-interval (0 to 15 lbs, 15 to 30 lbs)

**

Common ranges used as default setting.

* These procedures are for MS2220 StratosS Scanner/Diva Scale models only

.