Seawater connections, Seawater connections - general information – Mercury INSTALLATION MANUAL D7.3L D-TRONIC User Manual

Page 19

Advertising
background image

D7.3L D-TRONIC DIESEL ENGINES - BRAVO MODELS

Page 19 of 90

RETURN HOSE CONNECTION

76023

a

a -

Location on Water Circulation Pump for Hot Water Return (Bayonet Fitting

Replaces Plug)

Seawater Connections

D7.3L D-Tronic and D7.3L D-Tronic LD models must be equipped with a

through hull or

through transom

water supply

to ensure sufficient water flow to the engine. The transom

assembly needs to be modified with the water passage block-off plate kit (P/N 818304A1)

provided. It is necessary to cut the water hose that is located between the bell housing and

the gimbal housing. This allows water to continue through the drive for cooling. Refer to

“Drive Unit Seawater Routing.” outlined later. Read and observe the following to select the

proper seawater pickup hose, seacock size and seawater strainer.

Seawater Connections - General Information

SEAWATER PICKUP HOSE

Seawater inlet hose connections must be made with wire reinforced hose of adequate wall

thickness to prevent it from collapsing from pump suction. Be sure to secure hose connec-

tions with hose clamps. Secure hose to prevent contact with any moving parts of the engine.

Seawater Pickup Hose Inner Diameter

All Models

1-1/2 in. (38mm)

SEACOCK SIZE

Seacock used must have an internal cross-sectional area equal to or greater than seawater

inlet hose to prevent restricting water flow. Install valve in an area where it will be easily ac-

cessible and supported adequately to prevent hose fatigue. A brass ball or gate valve is re-

quired.

Seacock Size

(Internal Cross-Sectional Area Equal to or Greater Than Size Shown)

All Models

1-1/2 in. (38mm)

Advertising