Power Trim Pump

1. Mount pump in desired location.

IMPORTANT: Make hydraulic connections as quickly as possible to prevent oil from
leaking out of system. Be careful not to cross-thread or overtighten hose fittings.

75126

50630

75127

50632

a

c

d

e

f

g

b

a -

Black Hose (UP Circuit)

b -

Gray Hose (DOWN Circuit)

c -

Harness Connector

d -

Clamp

e -

Trim Limit Switch Wire (with Blue Sleeve) - to BLUE/WHITE Harness Wire

f -

Trim Limit Switch Wire (with Purple Sleeve) to PURPLE/WHITE Harness Wire

g -

Wire Retainer and Sta-Strap

2. Connect hydraulic hoses to trim pump. Torque fittings to 100-150 lb-in. (11-16 Nm).
3. Connect power trim pump control harness to trim pump. Secure with clamp.
4. Connect trim limit switch wires and secure with wire retainer and sta-strap.