1 the outdoor unit (odu), The outdoor unit (odu) – Motorola MotoWI4 PTP 600 Series User Manual

Page 31

Advertising
background image

29

Alternately, the network connection to a PTP 600 Series Bridge can be made using a

1000BaseSX Fiber Optic cable connected directly to the ODU. In this case power is still

provided over the 1000BaseT Ethernet connection. In the case of Fiber Optic cable failure the

PTP 600 Series Bridge will automatically fall back to the copper Ethernet connection

(provided the cable length <=100m [330 ft]). “PTP 600 Series Optical Interface Upgrade Kits”

can be obtained from your distributor, reseller or system integrator.

Power is fed into the PTP 600 Series Bridge PIDU Plus from the mains via a standard “figure

of eight” mains plug. Connection between the ODU and PIDU Plus is made using standard

CAT5e outdoor UV resistant cable. Connection between the PIDU Plus and the Network

Equipment is made using standard CAT5e cable.

3.3.1

The Outdoor Unit (ODU)

The ODU (Figure 3) is a self-contained unit. It houses both radio and networking electronics.

The ODU for the PTP 600 Series Bridge should only be deployed using the supplied PTP 600

Series Bridge PIDU Plus.

Figure 3 – PTP 600 Series Bridge Outdoor Unit (ODU)

Advertising