7.7.6

Grounding the Installation

The Outdoor Unit (ODU) must be properly grounded to protect against power surges. It is the

user’s responsibility to install the equipment in accordance with Section 810 of the National

Electric Code, ANSI/NFPA No.70-1984 or Section 54 of the Canadian Electrical Code or the

National Electrical Code in the country of installation. These codes describe correct

installation procedures for grounding the outdoor unit, mast, lead-in wire and discharge unit,

size of grounding conductors and connection requirements for grounding electrodes. It is

recommended that installation of the outdoor unit be contracted to a professional installer.

See Section 10 “Lightning Protection” for recommended grounding kits”.

7.7.7

Making the ODU Connection at the PTP 600 Series Bridge PIDU Plus

The ODU is connected to the PIDU Plus by means of a concealed RJ45 connector. The RJ45

connection has been placed inside the PIDU Plus hinged cover to prevent the user from

inadvertently plugging other equipment into the ODU RJ45 socket.

Warning: Plugging other equipment into the ODU RJ45 socket may damage the equipment

due to the non-standard techniques employed to inject DC power into the 1000BaseT

connection between the PIDU Plus and the ODU. Plugging the ODU into other equipment

may damage the ODU and/or the other equipment.

Step 1: Undo the retaining screw and hinge

back the cover.

Step 2: Plug in the ODU into the PIDU Plus

Cable ensuring that it snaps home