OM-1314 Page 13

2-7.

Electrical Service Guide

Input Voltage

230

Input Amperes At Rated Output

20.5

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

25

Min Input Conductor Size In AWG/Kcmil

14

Max Recommended Input Conductor Length In Feet (Meters)

64 (19)

Min Grounding Conductor Size In AWG/Kcmil

14

Reference: 1996 National Electrical Code (NEC)

S-0092-J

2-8.

Selecting A Location And Connecting Input Power

1

Rating Label

Supply correct input power.

2

Plug

3

Receptacle

Connect plug to receptacle.

4

Line Disconnect Device

See Section 2-7.

Y

Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.

ssb2.2* 1/94 – ST-801 504

1

18 in (457 mm) of
space for airflow

L1

L2

L1

L2

2

230 VAC, 1

Y

Always connect
grounding
conductor first.

= GND/PE

4

3

Y

Do not move or operate unit
where it could tip.