SECTION 4 – MAINTENANCE & TROUBLESHOOTING

4-1.

Maintenance

Y

Disconnect power
before maintaining.

.

Maintain more often
during severe conditions.

3 Months

Replace

Damaged Or

Unreadable

Labels

Clean And

Tighten

Weld

Connections

Repair Or

Replace
Cracked

Cables

And Cords

6 Months

Blow Out Or

Vacuum Inside

stat_maint – 2/96

4-2.

Fuse F1

Ref. ST-801 552

Y

Turn Off unit, disconnect in-
put power. Unlatch door and
remove wrapper.

1

Circuit Board PC1

2

Fuse F1 (See Parts List For
Rating)

If F1 opens, wire drive motor shuts
down. Replace F1 if open.

Reinstall wrapper, and latch door.

3/8 in

1

2

Tools Needed:

4-3.

Short Circuit Shutdown

If contact tip is shorted and sticks to workpiece, the unit shuts down, but fan runs. To resume operation, release gun
trigger, turn Off unit, and remove contact tip from workpiece. Check contact tip and replace if damaged. Turn On unit to
continue operation.

Advertising