4. stainless steel and 100% co2 weld parameters – Miller Electric Renegade 180 User Manual

Page 33

Advertising
background image

.

Complete Parts List available at www. MillerWelds.com

OM-228 042 Page 29

6-4. Stainless Steel And 100% CO2 Weld Parameters

Select Wire Type, Polarity, and Shielding

Wire Size

Material Thickness

Select Wire Type, Polarity, and Shielding

Gas

Wire Size

20 ga

18 ga

16 ga

14 ga

1/8 in.

3/16 in.

1/4 in.

5/16 in.

Shop Settings (Wall or Premise Power, 230 V 1 Ph)

Solid ER70S−6 (DCEP)

100% CO2 Shielding Gas

0.024

3.2/25

3.5/25

4.0/40

4.5/50

5.0/60

7.0/85

−−−

−−−

100% CO2 Shielding Gas

0.030

3.0/15

3.5/20

4.0/25

4.5/35

5.5/45

6.0/55

6.5/65

10.0/75

0.035

−−−

3.0/12

4.0/20

4.5/30

5.5/35

6.0/40

6.5/50

10.0/55

Stainless Steel (DCEP)

Tri Mix Shielding Gas

0.024

3.5/30

3.5/45

4.0/50

4.5/70

5.0/80

6.0/95

−−−

−−−

Tri−Mix Shielding Gas

90% HE/7.5% Ar/ 2.5% CO2

0.030

3.5/25

3.5/30

4.0/45

5.0/60

5.0/70

6.0/85

7.5/95

−−−

90% HE/7.5% Ar/ 2.5% CO2

0.035

−−−

2.5/20

3.5/25

4.0/40

4.5/50

6.0/65

7.5/80

−−−

Aluminum 4043 (DCEP)

100% Argon Shielding Gas

0.030

2.0/70

2.0/70

4.0/70

5.0/70

8.0/95

10/100

100% Argon Shielding Gas

0.035

2.5/65

4.0/60

5.0/65

8.0/90

10/90

Field Setting (Generator Power)

Solid ER70S−6 (DCEP)

100% CO2 Shielding Gas

0.024

3.5/25

3.5/25

4.0/40

4.5/50

5.0/60

10.0/70

−−−

−−−

100% CO2 Shielding Gas

0.030

3.0/15

3.5/20

4.0/25

5.0/35

6.0/45

10.0/55 10.0/65

−−−

0.035

−−−

3.0/12

4.0/20

10.0/30 10.0/35

−−−

−−−

−−−

Stainless Steel (DCEP)

Tri Mix Shielding Gas

0.024

3.5/30

3.5/45

4.0/50

5.5/70

10.0/80 10.0/95

−−−

−−−

Tri−Mix Shielding Gas

90% HE/7.5% Ar/ 2.5% CO2

0.030

4.5/25

4.5/30

6.0/45

10.0/60 10.0/70 10.0/85

−−−

−−−

90% HE/7.5% Ar/ 2.5% CO2

0.035

−−−

3.0/20

4.0/25

6.0/40

10.0/50

−−−

−−−

−−−

Aluminum 4043 (DCEP)

100% Argon Shielding Gas

0.030

4.0/70

4.0/70

6.0/70

10/75

100% Argon Shielding Gas

0.035

4.5/60

6.0/60

10/65

Advertising