Section 8 − maintenance, 1. power source routine maintenance – Miller Electric Renegade 180 User Manual

Page 35

Advertising
background image

.

Complete Parts List available at www. MillerWelds.com

OM-228 042 Page 31

SECTION 8 − MAINTENANCE

8-1. Power Source Routine Maintenance
.

Follow the storage procedure in the engine owner’s manual if the unit will not be used for an extended period.

Stop engine before maintaining.

.

See Engine Manual and Maintenance Label
for important start-up, service, and storage

information. Service engine more often if

used in severe conditions.

Recycle engine

fluids.

n = Check

Z = Change

~ = Clean

l = Replace

* To be done by Factory Authorized Service Agent

Reference

Every

8

Hours

Section 5-3

n Fuel Level

n Oil Level

~ Oil, Fuel Spills

Every

25

Hours

Section 8-9

~ Air Cleaner Precleaner

Every

50

Hours

~ Weld Terminals

Every

100

Hours

Engine

Manual,

Section 8-9

Z Oil

nl Air Cleaner Element

~ Cooling System

n Spark Plug Gap

n~ Battery Terminals

(Electric Start Models)

Every

200

Hours

l Unreadable Labels

Every

300

Hours

Engine

Manual

nValve Clearance*

Every

500

Hours

Engine

Manual

nl Weld Cables

n~ Slip Rings*

nl Brushes*

Every

1000

Hours

OR

~ Inside Unit

Advertising