4-12. Setting Internal DIP Switches

1

DIP Switch S1

2

DIP Switch S4 (Not For Customer Use)

DIP switch S1 allows the user to make a num-

ber of choices affecting unit operation.
w Defining Motor Speed (S1-7 & 8)
Switches 7 and 8 allow the user to define

whether the motor in use is standard speed

(50-780 inches per minute), or high speed

(92-1435 inches per minute).

.

Setting DIP switches allows the feeder to
display the proper wire speed. Setting

the DIP switches will not change the

speed range of the motors.

7 8

7 8

Position Settings And Results For DIP Switch S1

7 Off, 8 Off = Standard

speed motor (50-780 inch-

es per minute, or 1.2-19.8

meters per minute)

7 Off, 8 On = High speed

motor (92-1435 inches per

minute, or 2.3-36.4 meters

per minute)

.

When DIP switch positions are changed, the
unit must be turned Off and then On again in

order for the new settings to be active. DIP

switches are only read on power up.

803 198

2

1 2 3 4 5 6 7 8

O

N

.

In the DIP switch S1 illustrations,
the elevated slider on each switch

is shown in white. For example,

the switches above are all in the

Off position.

1