7-3. Diagnostics For User Defined Options

2

803 198

1

1

Front Panel

2

Front Panel Board PC20

User Defined Shutdown Error

Messages (Additional hardware

required for these to be functional)
If OPT1 and/or OPT2 are enabled

without additional hardware setup,

the following error messages will be

displayed on the front panel meters.

OPT1 and/or OPT2 must be dis-

abled.

.

Refer to Section 5-12 for cor-
rect setup procedures.

ERR

OPT1

Indicates a User Defined

Option Error

ERR

OPT2

SECTION 8 − MAINTENANCE & TROUBLESHOOTING

8-1. Routine Maintenance

!

Disconnect power

before maintaining.

.

Maintain more often
during severe conditions.

3 Months

Replace

unreadable

labels.

Clean and

tighten

weld

terminals.

Repair or

replace

cracked

weld

cable.

Check

14-pin cord.

Check gas

hose and

fittings.

Check gun

cable.

Replace

cracked

parts.

6 Months

Blow out or vacuum

inside. During heavy

service, clean

monthly.

Or

Clean

drive rolls.