Trouble

Remedy

Wire feeds, shielding gas flows, but elec-

trode wire is not energized.

Check interconnecting cord connections. If secure, check cord for continuity and repair or replace (see

Sections 4-5 and 4-6).

Wire feeder is on, meter(s) do not light

up, motor does not run, gas valve and

welding power source contactor do not

pull in.

Check and reset circuit breaker at welding power source.

Electrode wire feeding stops or feeds er-

ratically during welding.

Check gun trigger connection. See gun Owner’s Manual.

Check gun trigger. See gun Owner’s Manual.

Readjust hub tension and drive roll pressure (see Section 4-11).

Change to correct size drive roll (see Table 10-1).

Clean or replace dirty or worn drive roll.

Incorrect size or worn wire guides.

Replace contact tip or liner. See gun Owner’s Manual.

Remove weld spatter or foreign matter from around nozzle opening.

Have Factory Authorized Service Agency check drive motor or motor control board PC1.

Motor runs slowly.

Check for correct input voltage.

Wire does not feed until trigger is pulled,

but continues to feed after trigger is re-

leased, and trigger hold is not on.

Check for a short between welding gun trigger leads and weld cable. Repair short or replace welding gun.

Gas valve in feeder is rattling loudly

along with possible erratic or slow wire

feed speed.

Check for a short between welding gun trigger leads and weld cable. Repair short or replace welding gun.

Wire feeder power is on, displays light

up, but unit is inoperative.

Check welding gun trigger leads for continuity, and repair leads or replace gun.