0 technical data, Model number: hrv-150, Model number: hrv-210 – Maytag Ventilation Systems HRV-210 User Manual

Page 10: Cont’d), Energy performance, Ventilation performance

Advertising
background image

ENERGY PERFORMANCE

Supply

Net

Average

Sensible Recovery

Apparent Sensible

Latent Recovery

Temperature

Airflow

Power

Efficiency

Effectiveness

Moisture Transfer

°C

°F

l/s

cfm

Watts

%

%

0

32

51

109

92

70

77

-0.01

0

32

73

155

128

65

72

-0.02

0

32

102

215

191

62

70

-0.01

-25

-13

52

110

104

60

94

0.05

Total Recovery Efficiency

35

95

Not tested

ENERGY PERFORMANCE

Supply

Net

Average

Sensible Recovery

Apparent Sensible

Latent Recovery

Temperature

Airflow

Power

Efficiency

Effectiveness

Moisture Transfer

°C

°F

l/s

cfm

Watts

%

%

0

32

30

64

54

75

83

-0.03

0

32

46

97

78

67

74

0.01

0

32

65

138

124

64

72

-0.02

-25

-13

26

55

62

67

89

0.05

Total Recovery Efficiency

35

95

Not tested

10

MODEL NUMBER: HRV-150

Electrical requirements: 120 volts, 1.3 Amps
Exhaust Air Transfer Ratio: 0.05

4.3

P

ERFORMANCE

C

HARTS

(

CONT

D

)

4.0

Technical Data

(cont’d)

VENTILATION PERFORMANCE

External Static

Net Supply

Gross Air Flow

Pressure

Air Flow

Supply

Exhaust

Pa

in. w.g.

l/s

cfm

l/s

cfm

l/s

cfm

25

0.1

84

177

88

186

90

190

50

0.2

80

169

84

178

86

182

75

0.3

77

163

81

171

81

171

100

0.4

69

146

72

153

76

161

125

0.5

61

130

65

137

66

139

150

0.6

46

98

49

103

52

110

175

0.7

38

81

40

85

31

67

Note: Unit operating at maximum speed.

MODEL NUMBER: HRV-210

Electrical requirements: 120 volts, 1.9 Amps
Exhaust Air Transfer Ratio: 0.042

VENTILATION PERFORMANCE

External Static

Net Supply

Gross Air Flow

Pressure

Air Flow

Supply

Exhaust

Pa

in. w.g.

l/s

cfm

l/s

cfm

l/s

cfm

50

0.2

120

253

124

264

126

268

75

0.3

118

250

123

262

119

251

100

0.4

111

235

116

245

114

241

125

0.5

102

216

106

224

107

226

150

0.6

87

185

91

193

96

204

175

0.7

75

160

78

167

81

172

200

0.8

57

120

59

124

57

121

Note: Unit operating at maximum speed.

External Static Pressure - Pascals

(250 Pascals = 1” of water)

Gross Airflow - l/s (0.47 l/s = 1 cfm)

225

175

200

150

125

100

75

50

25

0

0

50

25

100

125

75

150

VG0039

External Static Pressure - Pascals

(250 Pascals = 1” of water)

Gross Airflow - l/s (0.47 L/s = 1 cfm)

225

175

200

150

125

100

75

50

25

0

0

50

25

100

125

75

150

VG0040

HEATING

COOLING

HEATING

COOLING

Supply
(l/s)
Exhaust
(l/s)

Supply
(l/s)
Exhaust
(l/s)

Advertising