Inserting the non-return flap 32, Inserting the non-return flap, Installation – Miele DA 229-2 User Manual

Page 32: Attaching the motor assembly

Advertising
background image

Inserting the non-return flap

^ If a non-return flap is not present in

the venting system, the

non-return

flap

supplied must be fitted into the

exhaust connection on the motor. The
flaps must open upwards.

^ The hood is designed for 6" (150 mm)

exhaust ducting. If 5" (125 mm) ex-
haust ducting is used the

reducing

collar

must be fitted into the exhaust

connection on the motor (see "Air ex-
traction").

Attaching the motor assembly

^ First loosely screw the two locking

nuts onto the threaded bolts on re-
taining plate A.
Leave a gap of

1

/

8

" (3 mm) for hang-

ing the motor on.

^ Fit the motor assembly onto the

hooks on retaining plate A and slide
down behind the nuts.

^ Tighten the nuts.

Installation

32